ติดต่อพนักงานขาย โทร: 0-868-1395, 0-2868-1127-9 แฟกซ์: 0-2458-1257 |
|
|
รหัสใบสินค้า : |
566 จำนวนผู้ชม ( 2980 ) คน |
|
|
ไขควงไฟฟ้า เดลโว่ delvo dlr5040a-we/dlr5340-we
ไขควงไฟฟ้า, เดลโว่, delvo, dlr5040a-we, dlr5340-we |
|
|
|
|
|
|
|
|
|
|
|
|
คำค้นหา: |
ไขควงไฟฟ้า, เดลโว่, delvo, dlr5040a-we, dlr5340-we, delvo, dlr5040a-we non-ce
screw fastening counter
delva. scenester oneto
work
oking
count
ter
features for prevention of human fastening errors and enhanced fastening management accuracy • ideally suited for the assembly lines of vehicles and electrical
equipment requiring reliable screw fastening • the controller receives signals from electric screwdrivers to provide
highly reliable screw fastening control • count return function: when a screw is loosened, a reverse signal
output from the electric screwdriver reverses the count by one • the count correction function does not count elevated screws or
double fastening • input voltage range from 100 to 240 v ac is acceptable in any part of the world (the screwdrivers to be used in combination with the counter require
input power supplies that are written on the respective nameplate) specifications
• link connection function: you can build up a simple sequential screw model
dlr5040a-we
tightening system by connecting the dlr5040a-we screw tightening count
1 - 99
counters in series without using any external controller such as a counting method
count-up/count-down
programmable controller count correction function
count normal fastening only
• driver lock function prevents unexpected start of screwdrivers self adjustable timer setting
0.01 to 0.99 sec.
• compact and lightweight (compared with our conventional models
decreased by 30 % in volume and by 38 % in mass) work detection function
yes (1 terminal) / no
• spc type screwdrivers for dlr5040a-we are designed on the basis external count input 2 terminals (parts a/ parts b)
of established transformerless screwdrivers work installation timer setting
oto 9.5 sec. ok output timer setting
0 to 9.5 sec.
link function ng alarm
on(1) / on(2) / off
when counters are connected and activated in the ok buzzer
on(1)/on(2) / on(3) / off
screw fastening sequence as shown below, all count return function
on/off
screwdrivers are on standby except the first one in ng judge timing
work set / driver on
the sequence. only when the first screw fastening is
finished, can the next screwdriver change from automatic / manual ok judge
auto / manual
standby to ready. when the last fastening in the screwdriver lock function
on/off
sequence is finished, the first screwdriver is once multiple link
up to 10 counters can be connected. again ready and the sequence can be repeated external inputs on terminal block sensor/ reset / link-in / parts a/parts b
again.
n.b. up to 10 screwdriver/counter sets can be external outputs on terminal block
ok/ng / link-out
connected to the link. parameter memory
parameters stored in internal nonvolatile memory input voltage
100 - 240 v ac, 50/60 hz external dimensions (mm (inch]) w100 x d120 x h60 (w3.94" x d4.72" x h2.36") mass (g (lbs]) 470 (1.04]
example of use together accessory: 2 m cord with ul three-prong plug. this product is for use outside japan.
with a sensor available in the market
dlr5340-we non-ce
delvo estr
features up to three sets screwdrivers can be connected to one counter • up to eight kinds of screw fastening conditions can be stored in
internal memory for a wide variety of assembly work count-up signal outputs • space saving • the count correction function does not count elevated screws or
double fastening as fastening errors • count return function: when a screw is loosened, a reverse signal output from the electric screwdriver reverses the count by one
onito
work
timer
specifications model
dlr5340-we count
0-99 counting method
count-up / count-down count correction function
count normal fastening only self adjustable timer setting
0.01 to 2.50 sec. work detection function
yes (1 terminal) / no work installation timer setting
0 to 9.5 sec. ok output timer setting
0 to 9.5 sec. ng alarm
on(1) /on(2)/off ok buzzer
on(1) / on(2) / on(3) / on(4) / on(5) / off count return function
on/off screwdriver lock function
on/off screwdriver cord connection
single cord connection (signal and power lines) external inputs on terminal block sensor/ reset / torque check/ch1/2/3 external outputs on terminal block ok/ng/count-up / driver a/b/c input voltage
100 - 240 v ac, 50/60 hz external dimensions (mm (inch]) w150 x d120 * h60 [w5.91" ~ d4.72" x h2.36") mass
(g (lbs))
620 (1.37] accessory: 2 m cord with ul three-prong plug. this product is for use outside japan.
, เดลโว่, DLR5040A-WE Non-CE
Screw Fastening Counter
delva. SCENESTER ONETO
WORK
OKING
COUNT
TER
Features For prevention of human fastening errors and enhanced fastening management accuracy • Ideally suited for the assembly lines of vehicles and electrical
equipment requiring reliable screw fastening • The controller receives signals from electric screwdrivers to provide
highly reliable screw fastening control • Count Return Function: When a screw is loosened, a reverse signal
output from the electric screwdriver reverses the count by one • The Count Correction Function does not count elevated screws or
double fastening • Input voltage range from 100 to 240 V AC is acceptable in any part of the world (The screwdrivers to be used in combination with the counter require
input power supplies that are written on the respective nameplate) Specifications
• Link Connection Function: You can build up a simple sequential screw Model
DLR5040A-WE
tightening system by connecting the DLR5040A-WE screw tightening Count
1 - 99
counters in series without using any external controller such as a Counting Method
Count-up/Count-down
programmable controller Count Correction Function
Count normal fastening only
• Driver Lock Function prevents unexpected start of screwdrivers Self Adjustable Timer Setting
0.01 to 0.99 sec.
• Compact and Lightweight (Compared with our conventional models
decreased by 30 % in volume and by 38 % in mass) Work Detection Function
Yes (1 terminal) / No
• SPC type screwdrivers for DLR5040A-WE are designed on the basis External Count Input 2 terminals (PARTS A/ PARTS B)
of established transformerless screwdrivers Work Installation Timer Setting
Oto 9.5 sec. OK Output Timer Setting
0 to 9.5 sec.
LINK Function NG Alarm
ON(1) / ON(2) / OFF
When counters are connected and activated in the OK Buzzer
ON(1)/ON(2) / ON(3) / OFF
screw fastening sequence as shown below, all Count Return Function
ON/OFF
screwdrivers are on standby except the first one in NG Judge Timing
WORK SET / DRIVER ON
the sequence. Only when the first screw fastening is
finished, can the next screwdriver change from Automatic / Manual OK Judge
AUTO / MANUAL
standby to ready. When the last fastening in the Screwdriver Lock Function
ON/OFF
sequence is finished, the first screwdriver is once Multiple Link
Up to 10 counters can be connected. again ready and the sequence can be repeated External Inputs on Terminal Block SENSOR/ RESET / LINK-IN / PARTS A/PARTS B
again.
N.B. Up to 10 screwdriver/counter sets can be External Outputs on Terminal Block
OK/NG / LINK-OUT
connected to the LINK. Parameter Memory
Parameters stored in internal nonvolatile memory Input Voltage
100 - 240 V AC, 50/60 Hz External Dimensions (mm (inch]) W100 x D120 x H60 (W3.94" x D4.72" x H2.36") Mass (g (lbs]) 470 (1.04]
Example of use together Accessory: 2 m cord with UL three-prong plug. This product is for use outside Japan.
with a sensor available in the market
DLR5340-WE Non-CE
delvo ESTR
Features Up to three sets screwdrivers can be connected to one counter • Up to eight kinds of screw fastening conditions can be stored in
internal memory for a wide variety of assembly work Count-up signal outputs • Space saving • The Count Correction Function does not count elevated screws or
double fastening as fastening errors • Count Return Function: When a screw is loosened, a reverse signal output from the electric screwdriver reverses the count by one
ONITO
WORK
TIMER
Specifications Model
DLR5340-WE Count
0-99 Counting Method
Count-up / Count-down Count Correction Function
Count normal fastening only Self Adjustable Timer Setting
0.01 to 2.50 sec. Work Detection Function
Yes (1 terminal) / No Work Installation Timer Setting
0 to 9.5 sec. OK Output Timer Setting
0 to 9.5 sec. NG Alarm
ON(1) /ON(2)/OFF OK Buzzer
ON(1) / ON(2) / ON(3) / ON(4) / ON(5) / OFF Count Return Function
ON/OFF Screwdriver Lock Function
ON/OFF Screwdriver Cord Connection
Single cord connection (Signal and power lines) External Inputs on Terminal Block SENSOR/ RESET / TORQUE CHECK/ch1/2/3 External Outputs on Terminal Block OK/NG/COUNT-UP / DRIVER A/B/C Input Voltage
100 - 240 V AC, 50/60 Hz External Dimensions (mm (inch]) W150 x D120 * H60 [W5.91" ~ D4.72" x H2.36") Mass
(g (lbs))
620 (1.37] Accessory: 2 m cord with UL three-prong plug. This product is for use outside Japan.
, 204, |
|
|
|
|
|
ติดต่อพนักงานขาย โทร: 0-868-1395, 0-2868-1127-9 แฟกซ์: 0-2458-1257 |
|
|